Electric Power System Equipment电力管理
Power Management2019年第22期
2019 No.22
浅谈光伏场区火灾预防措施
胡淑玲,成登明
(北京市东旭新能源投资有限公司,北京 100032)
[摘 要]目前我国地面集中式光伏电站的特点是发电设备设施简单、光伏场区占地面积大、设备多、杂草横生,智能运维技术不完善、专业运维人员数量不足,安全管理处于薄弱状态。通过风险分析,光伏电站主要存在触电、火灾及车辆伤害等问题。其中每年光伏场区不同季节均有火灾发生,其特点是蔓延快、损失重、难以控制。如何控制光伏场区火灾事故成为安全管理中的重中之重。本文主要针对光伏场区火灾预防工作,从人、机、环境和管理方面进行分析,提出预防措施,减少火灾事故发生。
[关键词]光伏场区;火灾;预防措施[中图分类号]TM615 [文献标志码]A [文章编号]1001–523X(2019)22–0149–02
Talking about the Fire Prevention Measures in the Photovoltaic Field
Hu Shu-ling,Cheng Deng-ming
[Abstract]At present, China’s ground-based photovoltaic power plants are characterized by simple power generation facilities, large area of photovoltaic field, large equipment, and weeds. The intelligent operation and maintenance technology is imperfect, the number of professional operation and maintenance personnel is insufficient, and the safety management is weak. status. Through risk analysis, PV power plants mainly suffer from electric shock, fire and vehicle damage. Among them, fires occur in different seasons in the photovoltaic field, which is characterized by rapid spread, heavy losses and difficult to control. How to control the fire accidents in the photovoltaic field has become the top priority in safety management. This paper focuses on the fire prevention work in photovoltaic field, analyzes people, machine, environment and management, and proposes preventive measures to reduce the occurrence of fire accidents.
[Keywords]photovoltaic field; fire; preventive measures1 光伏场区火灾特性
(1)具有显著的季节特点和民俗习惯特点。在每年的清明节、春耕、夏季、秋冬季(春节、祭祀)均有光伏电站火灾事故发生。不同时间段内引起火灾事故的危险源主要包括:祭祀、春耕烧荒、电气设备、高温、杂草、秸秆焚烧、烟花爆竹及外来火种等。
(2)光伏场区地理位置及对外交通条件对火灾救援不利,地面集中光伏电站大都建设在戈壁荒滩、农村周边等,距离城市较远,交通条件差,在火灾初期对社会专业救援、消防部门、森林消防等依靠性小,对电站运维人员、周边群众应急救援和应急物资储备依靠性强。
(3)杂草火灾隐患长期存在。光伏场区杂草高于组件,将遮挡组件发生热斑效应,发电量减少,持续遮挡组件易引发高温火灾;组件背板下的杂草接近组件,若组件高温异常易引发杂草火灾;内部或外部火源极易引起杂草、农业大棚易燃物起火。
(4)受周边村庄、农田环境影响。光伏场区周边距离村庄、农田距离较近(不足30m),导致春耕烧荒、春节鞭炮、烟头等外来火源极易进入光伏场区。2 预防措施
2.1 人的方面
期(如祭祀、烧荒时期等)应增加视频巡视次数,重点区域1次/小时进行巡视。在实际运维中,光伏电站视频监控设备常存在监控盲区或监控故障,运维人员应利用地势、巡检、配备望远镜等方式加强视频监控盲区或视频故障区的巡视工作。(4)光伏场区火灾中,多数因高温拉弧引起直流侧设备火灾。设备着火前常伴随发热现象,高温是火灾的前兆,巡检人员在巡检过程中随身携带红外检测仪,可随时对比、查看设备运行温度,判定设备运行情况,减少设备火灾概率。(5)光伏场区以每个箱变为一个单元,按照每个箱变不少于2具灭火器的要求配备灭火器,定期进行检查,保证消防器材处于有效状态。如图1、图2所示。
图1 组件遮挡热斑效应图例 图2 组件遮挡热斑效应图例
针对外部人员作业活动内容的不同,进行有针对性的安全告知(如清明节祭祀时对明火的要求,春耕时禁止焚烧要求,场区内农业种植、除草人员禁止吸烟等),设专人现场监督;带电作业严格执行“两票”制度。
2.2 物的方面
(1)光伏场区设置封闭的围栏,在道路、行人较多的地方,设置大门并上锁,定期巡视场区围栏破损情况,及时修复,保证封闭。
(2)场区围栏在出入口,临近道路、农田、村庄、墓地较近的地方,设置“禁止烟火”“高压危险”等安全警示标识和安全告知牌。
(3)光伏场区设置视频监控设备,保障视频监控设备完好、无监控盲区。运维人员应将视频巡视纳入日常工作中,在监控平台能随时查看光伏场区及周边实时情况,在防火高峰时
(6)光伏场区电缆种类较多,在电缆穿孔、洞的地方做好防火封堵。
(7)配备应急物资,如通用的铁扫把、消防灭火器等,另外企业根据电站周边环境及特点,配备合适的灭火器材,如:山地电站配置风力灭火机,农光互补电站配置消防车或水喷雾器等,能在火灾初期有效、快速灭火。在日常工作中做好应急物资的储存、维护工作,使其处于有效状态。
(8)光伏组件清洗不仅能提高发电量,还能降低热板效应引起的火灾。
2.3 环境方面
(1)光伏电站每年进行多次除草,夏季防遮挡性除草,秋季防火除草,除了有特殊要求的地区外,杂草清理至地面5 cm为标准,清理出的杂草全部外运,禁止堆放在光伏场区。(2)秋冬季除草的过程中,应同时在围栏周边建立防火隔离带,隔离外部火源进入光伏场区。防火隔离带建设因地制宜,可利用场区内外道路、排水沟等建设,也可将地面杂
2019.22 电力系统装备丨149
2019年第22期
2019 No.22
电力管理
Power Management电力系统装备
Electric Power System EquipmentΠ型锅炉高过高再管排卧式组合吊装方法
蔡中枢
(中国能源建设集团东北电力第二工程有限公司,辽宁大连 116000)
[摘 要]本文通过研究Π类型锅炉水平烟道区域受热面的结构特点,总结出一套整体组合吊装高再、高过管排的施工方法,与常规散片吊装方法相比节省了安装时间和安装费用。[关键词]Π锅炉水平烟道U型管排;卧式组合安装[中图分类号]TM76 [文献标志码]A [文章编号]1001–523X(2019)22–0150–02
Π-type Boiler High Over-high Re-pipe Row Horizontal Combination Lifting Method
Cai Zhong-shu
[Abstract]The author of this paper, by studying the structural characteristics of the heating surface of the horizontal flue area of the Π type boiler, summed up a set of construction methods for the overall combined hoisting high re-high and high tube slab, which saves the installation time compared with the conventional sling hoisting method. And installation costs.[Keywords]Π boiler horizontal flue U-tube row; horizontal combination installation1 引言
目前我国主流火力发电厂锅炉为“Π”型结构,在“Π”型结构锅炉炉膛上方的水平烟道区域布置了高温过热器和高温再热器管排,这些管排数量多,采用散片安装时占用主吊机械时间长,高空作业量大,增大了施工的风险和成本。
在安装水平烟道区域的高温再热器和高温过热器“U”型管排中,我们创新采用了“U”型管排和进、出口集箱在地面整体卧式组合、整体吊装的施工方法,该方法避免了“U”型管排单件安装的弊端,减少了高空作业量,提高了施工的安全性,优化了水平烟道内受热面的施工流程,缩短了总的施工工期,节省了机械费和人工费,具有明显的社会效益和经济效益。2 方法特点
(1)高温过热器U型管排和进、出口集箱在地面进行整
体卧式组合。
(2)与水冷壁组合件使用同一个吊装预留口,没有额外增加吊装开口。
(3)将高空作业转移到地面作业,提高了施工的安全性。(4)整体组合能有效控制管排的间距,提高了管排的安装质量。
(5)使锅炉高过管排的对口焊接和热处理工作提前,缩短受热面施工的总工期。3 工艺原理
根据现场机械的吊装能力和场地情况,确定U型管排组合件的宽度和重量。组合件吊装时,从顶板水冷壁吊装预留口进入炉膛。吊装高再组合件时需要吊车缓钩越过K2板梁,即先将组合件临时吊挂在K2板梁下,然后吊钩从K2后侧第二次起吊把组合件送到设计位置安装就位。吊装高过组合件
草清理至地面0 cm、深翻地表土等。若场区周边村庄、农田、坟地等距离场区不足30 m,应采取防火硬隔离措施。若光伏场区有农业大棚,还应将农业大棚与地面杂草有效隔离(建立排查沟、增加大棚基础高度、深翻土地等)。
2.4 管理方面
(1)加强教育培训和应急演练。加强安全教育培训,提高运维人员防火安全意识,火灾高发期紧绷安全弦;加强技术培训,提高运维人员故障处理能力;在日常工作中做好防火应急演练,面对火灾,沉着冷静,有序灭火。
(2)外部应急救援力量及防火安全宣传。建立与周边企业、村委会、镇政府、森林武警、消防大队等有效应急联系,做好防火安全宣传工作,将防火安全意识深植在周边群众心中,减少外来火源对光伏场区的威胁,若遇火情,能及时联动,积极参与救援。
(3)企业缴纳一切财产险,发生火灾后,及时请出险,获得理赔。
2.5 小结
(1)上述光伏电站防火安全措施应相互结合,相辅相成,形成动态防火体系,某一防火措施存在不足或缺失时,可通过其他防火措施来弥补。例如,防火隔离带未建设完成时,可加强视频巡视和现场巡视;灭火器压力不足须充装时,可采用备用灭火设备、视频监控或现场巡检等方式补充等等。(2)采用上述措施预防火灾的同时,运维人员应注意穿戴好劳动防护用品,避免触电等其他事故发生。
150丨电力系统装备 2019.22
(3)随着科学技术的发展,新的应急物质不断诞生,企业应广泛收集相关信息,采用科学手段、最实用的设备设施,有效防止火灾事故发生或扩大。
(4)由于光伏场区内道路交通条件差、行车难等特点,司机驾驶技术不过硬或心理素质不强常导致交通事故发生。3 结论
(1)本文遵循“安全第一,预防为主,防治结合”的原则,重在“预防”,从人、机、环境及管理方面防范火灾事故:建立封闭围栏,视频监控全覆盖,悬挂安全警示标识,建立封闭场区,减少外来人员对场区的威胁;光伏场区进行除草及防火隔离带建设,减少外来火源及在场区内的蔓延;对运维人员加强教育培训及应急演练,提高安全生产意识;对外来人员进行安全告知,带电作业严格执行“两票”操作;加强现场巡视、视频巡视、设备测温及组件清洗,减少设备火灾事故;建立外部应急联系、内部配置应急物资,有效预防火灾事故。(2)本论文以电站实际运维的安全管理经验为主,缺少深入的理论研究和详细的风险管控分析;倡导电站采用先进应急设备的同时,应关注其可能带来的负面效应。
参考文献
[1] 李润良.光伏电站运维管理的分析与探讨[J].科技创新与应用,2014(25):73-74.[2] 电力设备典型消防规程:DL5027—2015[S].[3] 光伏发电站安全规程:GBT35694—2017[S].
因篇幅问题不能全部显示,请点此查看更多更全内容